OM-154 501 Page 17
5-6. Troubleshooting
Welding Trouble Remedy
No weld output; wire does not feed. Check input power connections (see Section 3-7).
Reset circuit breaker CB1 (see Section 5-2).
Replace fuse F1 and/or F2 (see Section 5-3).
Replace building line fuse or reset circuit breaker if open (see Section 3-7).
Secure gun trigger plug in receptacle or repair leads (see Section 3-4).
Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled
(see Section 2-2).
No weld output; wire feeds. Connect work clamp to get good metal to metal contact.
Low weld output. Connect unit to proper input voltage or check for low line voltage (see Section 3-7).
Wire Drive/Gun Trouble Remedy
Electrode wire feeding stops during
welding.
Straighten gun cable and/or replace damaged parts.
Adjust drive roll pressure (see Section 3-9).
Readjust hub tension (see Section 3-8).
Clean or replace wire inlet guide or liner if dirty or plugged (see Section 5-4).
Replace drive rolls if worn or slipping (see Section 5-4).
Secure gun trigger plug in receptacle or repair leads (see Section 3-4).
Check and replace F1 and/or F2 (see Section 5-3).
Check and clear any restrictions at drive assembly and liner (see Section 5-3).
Have nearest Factory Authorized Service Agent check drive motor.
Check relay CR1, and replace if necessary.